Date Event
8/26/2011 10,740 hours of salt fog test (ASTM B 117) on Aluminum was posted on corrosion test page. Test result remains the same no rust or blistering and 0 undercutting/creep.
8/15/2011 AnCatt were been featured by paintsquare.com with title Protective Coatings are Metal Free .
8/15/2011 We received 12,420 hours of Salt fog (ASTM B 117) tests results and we were been featured by industrialcoatingsworld.com with title: Protective Coating Reaching New Heights in Sustainability and Performance.
5/5/2011 Salt fog (ASTM B 117) tests results of 10,404 hours have been received and posted on the Corrosion Test page.
4/6/2011 Salt fog (ASTM B 117) tests results of 9,372 hours and adhesion (ASTM D 4145 & ASTM D 3359) test results after 8,372 hours of salt fog have been received and posted on the Corrosion Test page.
1/26/2011 Photographs for 4,500 hrs of salt spray and 6,500 hrs of cyclic weathering for aluminum have been received and posted on the corrosion test page: http://www.ancatt.com/Corrosion_Test.html
10/7/2010 Our coated panels successfully reached 7,000 hours in the salt fog chamer, longer hours of testing is till under way.
6/29/2010 Our coated steel and aluminum panels successfully passed 4,000 hours of Prohesion test in England
4/13/2010 AnCatt Exhibited at the American Coating Show from April 13 to 15
4/7/2010 AnCatt Inc. and its innovative anti-corrosion technology were featured in March 2010 edition of NanoTimes Magazine.
http://content.yudu.com/A1n2ls/Nanotimes03-2010/
2/17/2010 Updated Technical Datasheet has been posted
2/8/2010 AnCatt Spoke at PACE Conference on "Environmentally Friendly Heavy-Duty Anti-Corrosion Coating" under session "Making Protective Coatings Green"
2/8/2010 AnCatt Inc. exhibited a novel heavy-metal free anticorrosion technology on PACE 2010 at Phoenix USA. The coated CRS panels after 5,000 hours of salt fog exposure are free of blister or rust, and the undercuttings / creeps are surprisingly less than 1 mm.
2/4/2010 AnCatt Received 5,000 Hours Salt Fog Exposure and Cyclic Weathering Test Results for Steel Panels With No Rust nor Blisters
2/4/2010 AnCatt Received 3,000 Hours Salt Fog Exposure and Cyclic Weathering Test Results for Aluminum Panels With No Rust nor Blisters

 